NAG CL Interface
d02pqc (ivp_rkts_setup)
1
Purpose
d02pqc is a setup function which must be called prior to the first call of either of the integration functions
d02pec,
d02pfc and
d02pgc.
2
Specification
void |
d02pqc (Integer n,
double tstart,
double tend,
const double yinit[],
double tol,
const double thresh[],
Nag_RK_method method,
Nag_ErrorAssess errass,
double hstart,
Integer iwsav[],
double rwsav[],
NagError *fail) |
|
The function may be called by the names: d02pqc or nag_ode_ivp_rkts_setup.
3
Description
d02pqc and its associated functions (
d02pec,
d02pfc,
d02pgc,
d02phc,
d02pjc,
d02prc,
d02psc,
d02ptc and
d02puc) solve the initial value problem for a first-order system of ordinary differential equations. The functions, based on Runge–Kutta methods and derived from RKSUITE (see
Brankin et al. (1991)), integrate
where
is the vector of
solution components and
is the independent variable.
The integration proceeds by steps from the initial point
towards the final point
. An approximate solution
is computed at each step. For each component
, for
, the error made in the step, i.e., the local error, is estimated. The step size is chosen automatically so that the integration will proceed efficiently while keeping this local error estimate smaller than a tolerance that you specify by means of arguments
tol and
thresh.
d02pec can be used to solve the ‘usual task’, namely integrating the system of differential equations to obtain answers at points you specify.
d02pfc is used for more ‘complicated’ tasks where
can readily be coded within a function argument and high-order interpolation is not required.
d02pgc is used for the most ‘complicated’ tasks where
is best evaluated outside the integrator or where high-order interpolation is required.
You should consider carefully how you want the local error to be controlled. Essentially the code uses relative local error control, with
tol being the desired relative accuracy. For reliable computation, the code must work with approximate solutions that have some correct digits, so there is an upper bound on the value used for
tol. It is impossible to compute a numerical solution that is more accurate than the correctly rounded value of the true solution, so you are not allowed to specify
tol too small for the precision you are using. The magnitude of the local error in
on any step will not be greater than
where
is an average magnitude of
over the step. If
is smaller than the current value of
, this is a relative error test and
tol indicates how many significant digits you want in
. If
is larger than the current value of
, this is an absolute error test with tolerance
. Relative error control is the recommended mode of operation, but pure relative error control,
, is not permitted. See
Section 9 for further information about error control.
d02pec,
d02pfc and
d02pgc control local error rather than the true (global) error, the difference between the numerical and true solution. Control of the local error controls the true error indirectly. Roughly speaking, the code produces a solution that satisfies the differential equation with a discrepancy bounded in magnitude by the error tolerance. What this implies about how close the numerical solution is to the true solution depends on the stability of the problem. Most practical problems are at least moderately stable, and the true error is then comparable to the error tolerance. To judge the accuracy of the numerical solution, you could reduce
tol substantially, e.g., use
, and solve the problem again. This will usually result in a rather more accurate solution, and the true error of the first integration can be estimated by comparison. Alternatively, a global error assessment can be computed automatically using the argument
errass.
Because indirect control of the true error by controlling the local error is generally satisfactory and because both ways of assessing true errors cost twice, or more, the cost of the integration itself, such assessments are used mostly for spot checks, selecting appropriate tolerances for local error control, and exploratory computations.
d02pec,
d02pfc and
d02pgc each implement three Runge–Kutta formula pairs, and you must select one for the integration. The best choice for
method depends on the problem. The order of accuracy is
,
and
respectively. As a rule, the smaller
tol is, the larger you should take the order of the
method. If the components
thresh are small enough that you are effectively specifying relative error control, experience suggests
tol |
efficient method |
|
order and pair |
|
order and pair |
|
order and pair |
The overlap in the ranges of tolerances appropriate for a given
method merely reflects the dependence of efficiency on the problem being solved. Making
tol smaller will normally make the integration more expensive. However, in the range of tolerances appropriate to a
method, the increase in cost is modest. There are situations for which one
method, or even this kind of code, is a poor choice. You should not specify a very small value for
, when the
th solution component might vanish. In particular, you should not do this when
. If you do, the code will have to work hard with any value for
method to compute significant digits, but the lowest order method is a particularly poor choice in this situation. All three methods are inefficient when the problem is ‘stiff’. If it is only mildly stiff, you can solve it with acceptable efficiency with the order
and
pair, but if it is moderately or very stiff, a code designed specifically for such problems will be much more efficient. The higher the order the more smoothness is required of the solution in order for the method to be efficient.
When assessment of the true (global) error is requested, this error assessment is updated at each step. Its value can be obtained at any time by a call to
d02puc. The code monitors the computation of the global error assessment and reports any doubts it has about the reliability of the results. The assessment scheme requires some smoothness of
, and it can be deceived if
is insufficiently smooth. At very crude tolerances the numerical solution can become so inaccurate that it is impossible to continue assessing the accuracy reliably. At very stringent tolerances the effects of finite precision arithmetic can make it impossible to assess the accuracy reliably. The cost of this is roughly twice the cost of the integration itself with the 5th and 8th order methods, and three times with the 3rd order method.
The first step of the integration is critical because it sets the scale of the problem. The integrator will find a starting step size automatically if you set the argument
hstart to
. Automatic selection of the first step is so effective that you should normally use it. Nevertheless, you might want to specify a trial value for the first step to be certain that the code recognizes the scale on which phenomena occur near the initial point. Also, automatic computation of the first step size involves some cost, so supplying a good value for this step size will result in a less expensive start. If you are confident that you have a good value, provide it via the argument
hstart.
4
References
Brankin R W, Gladwell I and Shampine L F (1991) RKSUITE: A suite of Runge–Kutta codes for the initial value problems for ODEs SoftReport 91-S1 Southern Methodist University
5
Arguments
-
1:
– Integer
Input
-
On entry: , the number of ordinary differential equations in the system to be solved by the integration function.
Constraint:
.
-
2:
– double
Input
-
On entry: the initial value of the independent variable, .
-
3:
– double
Input
-
On entry: the final value of the independent variable,
, at which the solution is required.
tstart and
tend together determine the direction of integration.
Constraint:
must be distinguishable from
tstart for the method and the precision of the machine being used.
-
4:
– const double
Input
-
On entry: , the initial values of the solution,
, for .
-
5:
– double
Input
-
On entry: a relative error tolerance. The actual tolerance used is ; that is, the minimum tolerance is set at times machine precision and the maximum tolerance is set at .
-
6:
– const double
Input
-
On entry: a vector of thresholds. For the
th component, the actual threshold used is
, where
is the value returned by
X02AMC.
-
7:
– Nag_RK_method
Input
-
On entry: the Runge–Kutta method to be used.
- A pair is used.
- A pair is used.
- A pair is used.
Constraint:
, or .
-
8:
– Nag_ErrorAssess
Input
-
On entry: specifies whether a global error assessment is to be computed with the main integration. specifies that it is.
Constraint:
or .
-
9:
– double
Input
-
On entry: a value for the size of the first step in the integration to be attempted. The absolute value of
hstart is used with the direction being determined by
tstart and
tend. The actual first step taken by the integrator may be different to
hstart if the underlying algorithm determines that
hstart is unsuitable. If
then the size of the first step is computed automatically.
Suggested value:
.
-
10:
– Integer
Communication Array
-
-
11:
– double
Communication Array
-
On exit: the contents of the communication arrays must not be changed prior to calling one of the integration functions.
-
12:
– NagError *
Input/Output
-
The NAG error argument (see
Section 7 in the Introduction to the NAG Library CL Interface).
6
Error Indicators and Warnings
- NE_ALLOC_FAIL
-
Dynamic memory allocation failed.
See
Section 3.1.2 in the Introduction to the NAG Library CL Interface for further information.
- NE_BAD_PARAM
-
On entry, argument had an illegal value.
- NE_INT
-
On entry, .
Constraint: .
- NE_INTERNAL_ERROR
-
An internal error has occurred in this function. Check the function call and any array sizes. If the call is correct then please contact
NAG for assistance.
See
Section 7.5 in the Introduction to the NAG Library CL Interface for further information.
On entry, too much workspace required.
Workspace provided was , workspace required is .
- NE_NO_LICENCE
-
Your licence key may have expired or may not have been installed correctly.
See
Section 8 in the Introduction to the NAG Library CL Interface for further information.
- NE_REAL_2
-
On entry, .
Constraint: .
On entry,
tstart is too close to
tend.
, but this quantity should be at least
.
7
Accuracy
Not applicable.
8
Parallelism and Performance
d02pqc is not threaded in any implementation.
If
d02pfc and
d02pgc is to be used for the integration then the value of the argument
tend may be reset during the integration without the overhead associated with a complete restart; this can be achieved by a call to
d02prc.
It is often the case that a solution component (the
th, say) is of no interest when it is smaller in magnitude than a certain threshold. You can inform the code of this by setting the
th component of
thresh to this threshold. In this way you avoid the cost of computing significant digits in the
th component of
when it is smaller than the threshold of interest. This matter is important when a component of
vanishes, and in particular, when the initial value is zero. An appropriate threshold depends on the general size of
in the course of the integration. Physical reasoning may help you select suitable threshold values. If you do not know what to expect of
, you can find out by a preliminary integration using
d02pec with nominal values of
thresh. As
d02pec integrates by steps in time, it stores, for each component, the largest magnitude of solution computed so far; these values are output in the array
ymax. This can help determine more appropriate values for
thresh for an accurate integration. For example, the values in
thresh could be set to
times the final value of
ymax.
10
Example
See Section 10 in
d02pec,
d02pfc,
d02prc,
d02psc and
d02puc.