NAG AD Library
x10bf_a1w_f (callback_​write_​real_a1w)

1 Purpose

x10bf_a1w_f writes a real value into a callback data object created by x10ba_a1w_f.

2 Specification

Fortran Interface
Subroutine x10bf_a1w_f ( cb_handle, x, ifail)
Integer, Intent (Inout) :: ifail
Real (Kind=nag_wp), Intent (In) :: x
Type (c_ptr), Intent (Inout) :: cb_handle
C++ Header Interface
#include <nagad.h>
extern "C" {
void  x10bf_a1w_f_ (void *&cb_handle, const double &x, Integer &ifail)
}
The routine may be called by the names x10bf_a1w_f or nagf_adutils_callback_write_real_a1w.

3 Description

For routines where it is necessary to perform callback operations via one or more companion callbacks, data must be passed between the procedure argument and any such companion callback via a callback data object as created by x10ba_a1w_f. x10bf_a1w_f can be used to insert a real value into the callback data object. In this way real values can be communicated between a procedure argument and its companion callbacks.
Note that data must be written to and read from the callback data object in strict order without omission.

4 References

None.

5 Arguments

1: cb_handle Type (c_ptr) Input/Output
On entry: will contain a handle to the callback data object.
On exit: will contain a handle to the updated callback data object.
2: x Real (Kind=nag_wp) Input
On entry: a real value, x, to be inserted into the callback data object.
3: ifail Integer Input/Output
On entry: ifail must be set to 0, -1 or 1 to set behaviour on detection of an error; these values have no effect when no error is detected.
A value of 0 causes the printing of an error message and program execution will be halted; otherwise program execution continues. A value of -1 means that an error message is printed while a value of 1 means that it is not.
If halting is not appropriate, the value -1 or 1 is recommended. If message printing is undesirable, then the value 1 is recommended. Otherwise, the value 0 is recommended. When the value -1 or 1 is used it is essential to test the value of ifail on exit.
On exit: ifail=0 unless the routine detects an error or a warning has been flagged (see Section 6).

6 Error Indicators and Warnings

If on entry ifail=0 or -1, explanatory error messages are output on the current error message unit (as defined by x04aaf).
Errors or warnings detected by the routine:
ifail=1
On entry, cb_handle does not define a valid handle to a NAG AD callback data object. It has not been initialized or has been corrupted.
ifail=-99
An unexpected error has been triggered by this routine. Please contact NAG.
See Section 7 in the Introduction to the NAG Library FL Interface for further information.
ifail=-399
Your licence key may have expired or may not have been installed correctly.
See Section 8 in the Introduction to the NAG Library FL Interface for further information.
ifail=-999
Dynamic memory allocation failed.
See Section 9 in the Introduction to the NAG Library FL Interface for further information.

7 Accuracy

Not applicable.

8 Parallelism and Performance

x10bf_a1w_f is not threaded in any implementation.

9 Further Comments

None.

10 Example

See examples for computational routines in the NAG AD Library, for example, Section 10 in c05ay_a1w_f.