e02cac forms an approximation to the weighted, least squares Chebyshev series surface fit to data arbitrarily distributed on lines parallel to one independent coordinate axis.
The function may be called by the names: e02cac, nag_fit_dim2_cheb_lines or nag_2d_cheb_fit_lines.
3Description
e02cac determines a bivariate polynomial approximation of degree in and in to the set of data points , with weights , for and . That is, the data points are on lines , but the values may be different on each line. The values of and are prescribed by you (for guidance on their choice, see Section 9). The function is based on the method described in Sections 5 and 6 of Clenshaw and Hayes (1965).
The polynomial is represented in double Chebyshev series form with arguments and . The arguments lie in the range to and are related to the original variables and by the transformations
Here and are set by the function to, respectively, the largest and smallest value of , but and are functions of prescribed by you (see Section 9). For this function, only their values and at each are required. For each , must not be less than the largest on the line , and, similarly, must not be greater than the smallest .
The double Chebyshev series can be written as
where is the Chebyshev polynomial of the first kind of degree with argument , and is similarly defined. However, the standard convention, followed in this function, is that coefficients in the above expression which have either or zero are written as , instead of simply , and the coefficient with both and equal to zero is written as . The series with coefficients output by the function should be summed using this convention. e02cbc is available to compute values of the fitted function from these coefficients.
The function first obtains Chebyshev series coefficients , for , of the weighted least squares polynomial curve fit of degree in to the data on each line , for , in turn, using an auxiliary function. The same function is then called times to fit , for , by a polynomial of degree in , for each . The resulting coefficients are the required .
You can force the fit to contain a given polynomial factor. This allows for the surface fit to be constrained to have specified values and derivatives along the boundaries , , and or indeed along any lines constant or constant (see Section 8 of Clenshaw and Hayes (1965)).
4References
Clenshaw C W and Hayes J G (1965) Curve and surface fitting J. Inst. Math. Appl.1 164–183
Hayes J G (ed.) (1970) Numerical Approximation to Functions and Data Athlone Press, London
5Arguments
1: – const IntegerInput
On entry: must be set to , the number of data values on the line , for .
Constraint:
, for .
2: – IntegerInput
On entry: the number of lines constant on which data points are given.
Constraint:
.
3: – IntegerInput
On entry: , the required degree of in the fit.
Constraint:
for , , where is the number of distinct values with nonzero weight on the line . See Section 9.
4: – IntegerInput
On entry: , the required degree of in the fit.
Constraints:
;
.
5: – const doubleInput
Note: the dimension, dim, of the array x
must be at least
.
On entry: the values of the data points. The sequence must be
all points on , followed by
all points on , followed by
all points on .
Constraint:
for each , the values must be in nondecreasing order.
6: – const doubleInput
On entry: must contain the value of line , for , on which data is given.
Constraint:
the values must be in strictly increasing order.
7: – const doubleInput
Note: the dimension, dim, of the array f
must be at least
.
On entry: , the data values of the dependent variable in the same sequence as the values.
8: – const doubleInput
Note: the dimension, dim, of the array w
must be at least
.
On entry: the weights to be assigned to the data points, in the same sequence as the values. These weights should be calculated from estimates of the absolute accuracies of the , expressed as standard deviations, probable errors or some other measure which is of the same dimensions as . Specifically, each should be inversely proportional to the accuracy estimate of . Often weights all equal to unity will be satisfactory. If a particular weight is zero, the corresponding data point is omitted from the fit.
9: – doubleOutput
Note: the dimension, dim, of the array a
must be at least
.
On exit: contains the Chebyshev coefficients of the fit. is the coefficient of Section 3 defined according to the standard convention. These coefficients are used by e02cbc to calculate values of the fitted function.
10: – const doubleInput
On entry: must contain , the lower end of the range of on the line , for . It must not be greater than the lowest data value of on the line. Each is scaled to in the fit. (See also Section 9.)
11: – const doubleInput
On entry: must contain , the upper end of the range of on the line , for . It must not be less than the highest data value of on the line. Each is scaled to in the fit. (See also Section 9.)
Constraint:
.
12: – const doubleInput
On entry: must contain the coefficient of the Chebyshev polynomial of degree in , in the Chebyshev series representation of the polynomial factor in which you require the fit to contain, for . These coefficients are defined according to the standard convention of Section 3.
Constraint:
must be nonzero, unless , in which case nux is ignored.
13: – IntegerInput
On entry: , where is the degree of a polynomial factor in which you require the fit to contain. (See Section 3, last paragraph.)
If this option is not required, inuxp1 should be set equal to .
Constraint:
.
14: – const doubleInput
On entry: must contain the coefficient of the Chebyshev polynomial of degree in , in the Chebyshev series representation of the polynomial factor which you require the fit to contain, for . These coefficients are defined according to the standard convention of Section 3.
Constraint:
must be nonzero, unless , in which case nuy is ignored.
15: – IntegerInput
On entry: , where is the degree of a polynomial factor in which you require the fit to contain. (See Section 3, last paragraph.) If this option is not required, inuyp1 should be set equal to .
16: – NagError *Input/Output
The NAG error argument (see Section 7 in the Introduction to the NAG Library CL Interface).
6Error Indicators and Warnings
NE_ALLOC_FAIL
Dynamic memory allocation failed.
See Section 3.1.2 in the Introduction to the NAG Library CL Interface for further information.
NE_BAD_PARAM
On entry, argument had an illegal value.
NE_INT
On entry, .
Constraint: .
On entry, .
Constraint: .
On entry, .
Constraint: .
On entry, .
Constraint: .
On entry, .
Constraint: .
NE_INT_2
On entry, and .
Constraint: .
On entry, and .
Constraint: .
NE_INT_3
On entry, , and .
Constraint: .
On entry, , and .
Constraint: and
On entry, , and .
Constraint: .
NE_INT_ARRAY
On entry, , , and .
Constraint: .
On entry, , , and .
Constraint: if , ; if , .
NE_INTERNAL_ERROR
An internal error has occurred in this function. Check the function call and any array sizes. If the call is correct then please contact NAG for assistance.
See Section 7.5 in the Introduction to the NAG Library CL Interface for further information.
NE_NO_LICENCE
Your licence key may have expired or may not have been installed correctly.
See Section 8 in the Introduction to the NAG Library CL Interface for further information.
NE_NON_ZERO_WEIGHTS
On entry, the number of distinct x values with nonzero weight on is less than : , , and .
NE_NOT_NON_DECREASING
On entry, the data x values are not nondecreasing for : and .
NE_NOT_STRICTLY_INCREASING
On entry, , and .
Constraint: .
NE_REAL_ARRAY
On entry, and do not span the data x values on : , , and .
7Accuracy
No error analysis for this method has been published. Practical experience with the method, however, is generally extremely satisfactory.
8Parallelism and Performance
e02cac is threaded by NAG for parallel execution in multithreaded implementations of the NAG Library.
Please consult the X06 Chapter Introduction for information on how to control and interrogate the OpenMP environment used within this function. Please also consult the Users' Note for your implementation for any additional implementation-specific information.
9Further Comments
The time taken is approximately proportional to .
The reason for allowing and (which are used to normalize the range of ) to vary with is that unsatisfactory fits can result if the highest (or lowest) data values of the normalized on each line are not approximately the same. (For an explanation of this phenomenon, see page 176 of Clenshaw and Hayes (1965).) Commonly in practice, the lowest (for example) data values , while not being approximately constant, do lie close to some smooth curve in the plane. Using values from this curve as the values of , different in general on each line, causes the lowest transformed data values to be approximately constant. Sometimes, appropriate curves for and will be clear from the context of the problem (they need not be polynomials). If this is not the case, suitable curves can often be obtained by fitting to the lowest data values and to the corresponding highest data values of , low degree polynomials in , using function e02adc, and then shifting the two curves outwards by a small amount so that they just contain all the data between them. The complete curves are not in fact supplied to the present function, only their values at each ; and the values simply need to lie on smooth curves. More values on the complete curves will be required subsequently, when computing values of the fitted surface at arbitrary values.
Naturally, a satisfactory approximation to the surface underlying the data cannot be expected if the character of the surface is not adequately represented by the data. Also, as always with polynomials, the approximating function may exhibit unwanted oscillations (particularly near the ends of the ranges) if the degrees and are taken greater than certain values, generally unknown but depending on the total number of coefficients should be significantly smaller than, say not more than half, the total number of data points. Similarly, should be significantly smaller than most (preferably all) the , and significantly smaller than . Closer spacing of the data near the ends of the and ranges is an advantage. In particular, if , for and , for , (thus for all ), then the values and (so that the polynomial passes exactly through all the data points) should not give unwanted oscillations. Other datasets should be similarly satisfactory if they are everywhere at least as closely spaced as the above cosine values with replaced by and (more precisely, if for every the largest interval between consecutive values of , for , is not greater than , and similarly for the ). The polynomial obtained should always be examined graphically before acceptance. Note that, for this purpose it is not sufficient to plot the polynomial only at the data values of and : intermediate values should also be plotted, preferably via a graphics facility.
Provided the data are adequate, and the surface underlying the data is of a form that can be represented by a polynomial of the chosen degrees, the function should produce a good approximation to this surface. It is not, however, the true least squares surface fit nor even a polynomial in and , the original variables (see Section 6 of Clenshaw and Hayes (1965), ), except in certain special cases. The most important of these is where the data values of are the same on each line , (i.e., the data points lie on a rectangular mesh in the plane), the weights of the data points are all equal, and and are both constants (in this case they should be set to the largest and smallest data values of , respectively).
If the dataset is such that it can be satisfactorily approximated by a polynomial of degrees and , say, then if higher values are used for and in the function, all the coefficients for or will take apparently random values within a range bounded by the size of the data errors, or rather less. (This behaviour of the Chebyshev coefficients, most readily observed if they are set out in a rectangular array, closely parallels that in curve-fitting, examples of which are given in Section 8 of Hayes (1970).) In practice, therefore, to establish suitable values of and , you should first be seeking (within the limitations discussed above) values for and which are large enough to exhibit the behaviour described. Values for and should then be chosen as the smallest which do not exclude any coefficients significantly larger than the random ones. A polynomial of degrees and should then be fitted to the data.
If the option to force the fit to contain a given polynomial factor in is used and if zeros of the chosen factor coincide with data values on any line, then the effective number of data points on that line is reduced by the number of such coincidences. A similar consideration applies when forcing the -direction. No account is taken of this by the function when testing that the degrees and have not been chosen too large.
10Example
This example reads data in the following order, using the notation of the argument list for e02cac above:
The data points are fitted using e02cac, and then the fitting polynomial is evaluated at the data points using e02cbc.