NAG AD Library
x10bb_a1w_f (callback_​insert_a1w)

Note: a1w denotes that first order adjoints are computed in working precision; this has the corresponding argument type nagad_a1w_w_rtype. Further implementations, for example for higher order differentiation or using the tangent linear approach, may become available at later marks of the NAG AD Library. The method of codifying AD implementations in the routine name and corresponding argument types is described in the NAG AD Library Introduction.
Settings help

AD Name Style:


AD Specification Language:

1 Purpose

x10bb_a1w_f inserts the locations of cb_handle and of companion AD callback into the internal data structure used by the NAG AD Library.

2 Specification

Fortran Interface
Subroutine x10bb_a1w_f ( cb_handle, cb_loc, ifail)
Integer, Intent (Inout) :: ifail
Type (c_ptr), Intent (In) :: cb_handle
Type (c_funptr), Intent (In) :: cb_loc
C++ Header Interface
#include <nagad.h>
extern "C" {
void  x10bb_a1w_f_ (void *&cb_handle, void *&cb_loc, Integer &ifail)
}
The routine may be called by the names x10bb_a1w_f or nagf_adutils_callback_insert_a1w.

3 Description

x10bb_a1w_f inserts the locations of cb_handle and of companion AD callback into the internal data structure used by the NAG AD Library.

4 References

None.

5 Arguments

1: cb_handle Type (c_ptr) Input
On entry: a handle to the callback data object as created by a prior call to x10ba_a1w_f.
2: cb_loc Type (c_funptr) Input
On entry: the location of the user-supplied AD symbolic callback as returned by the intrinsic c_funloc with the callback name the same as the argument.
3: ifail Integer Input/Output
On entry: ifail must be set to 0, -1 or 1 to set behaviour on detection of an error; these values have no effect when no error is detected.
A value of 0 causes the printing of an error message and program execution will be halted; otherwise program execution continues. A value of -1 means that an error message is printed while a value of 1 means that it is not.
If halting is not appropriate, the value -1 or 1 is recommended. If message printing is undesirable, then the value 1 is recommended. Otherwise, the value 0 is recommended. When the value -1 or 1 is used it is essential to test the value of ifail on exit.
On exit: ifail=0 unless the routine detects an error or a warning has been flagged (see Section 6).

6 Error Indicators and Warnings

If on entry ifail=0 or -1, explanatory error messages are output on the current error message unit (as defined by x04aaf).
Errors or warnings detected by the routine:
ifail=1
On entry, cb_handle does not define a valid handle to a NAG AD callback data object. It has not been initialized or has been corrupted.
ifail=-99
An unexpected error has been triggered by this routine. Please contact NAG.
See Section 7 in the Introduction to the NAG Library FL Interface for further information.
ifail=-399
Your licence key may have expired or may not have been installed correctly.
See Section 8 in the Introduction to the NAG Library FL Interface for further information.
ifail=-999
Dynamic memory allocation failed.
See Section 9 in the Introduction to the NAG Library FL Interface for further information.

7 Accuracy

Not applicable.

8 Parallelism and Performance

x10bb_a1w_f is not threaded in any implementation.

9 Further Comments

None.

10 Example

See examples for computational routines in the NAG AD Library, for example, Section 10 in c05ay_a1w_f.