NAG C Library Function Document

nag_tsa_spectrum_univar_cov (g13cac)

1
Purpose

nag_tsa_spectrum_univar_cov (g13cac) calculates the smoothed sample spectrum of a univariate time series using one of four lag windows – rectangular, Bartlett, Tukey or Parzen window.

2
Specification

#include <nag.h>
#include <nagg13.h>
void  nag_tsa_spectrum_univar_cov (Integer nx, Integer mtx, double px, Integer iw, Integer mw, Integer ic, Integer nc, double c[], Integer kc, Integer l, Nag_LoggedSpectra lg_spect, Integer nxg, double xg[], Integer *ng, double stats[], NagError *fail)

3
Description

The smoothed sample spectrum is defined as
f^ω=12π C0+2k=1 M-1wkCkcosωk ,  
where M is the window width, and is calculated for frequency values
ωi=2πiL,  i=0,1,,L/2,  
where  denotes the integer part.
The autocovariances Ck may be supplied by you, or constructed from a time series x1,x2,,xn, as
Ck=1nt=1 n-kxtxt+k,  
the fast Fourier transform (FFT) being used to carry out the convolution in this formula.
The time series may be mean or trend corrected (by classical least squares), and tapered before calculation of the covariances, the tapering factors being those of the split cosine bell:
121-cosπ t-12/T, 1tT 121-cosπ n-t+12/T, n+ 1-Ttn 1, otherwise,  
where T= np2  and p is the tapering proportion.
The smoothing window is defined by
wk=W kM ,  kM-1,  
which for the various windows is defined over 0α<1 by
rectangular:
Wα=1  
Bartlett:
Wα = 1-α  
Tukey:
Wα=121+cosπα  
Parzen:
Wα= 1- 6α2+ 6α3, 0α12 Wα= 2 1-α 3, 12<α< 1.  
The sampling distribution of f^ω is approximately that of a scaled χd2 variate, whose degrees of freedom d is provided by the function, together with multiplying limits mu, ml from which approximate 95% confidence intervals for the true spectrum fω may be constructed as ml × f ^ ω , mu × f ^ ω . Alternatively, log f^ω may be returned, with additive limits.
The bandwidth b of the corresponding smoothing window in the frequency domain is also provided. Spectrum estimates separated by (angular) frequencies much greater than b may be assumed to be independent.

4
References

Bloomfield P (1976) Fourier Analysis of Time Series: An Introduction Wiley
Jenkins G M and Watts D G (1968) Spectral Analysis and its Applications Holden–Day

5
Arguments

1:     nx IntegerInput
On entry: n, the length of the time series.
Constraint: nx1.
2:     mtx IntegerInput
On entry: if covariances are to be calculated by the function (ic=0), mtx must specify whether the data are to be initially mean or trend corrected.
mtx=0
For no correction.
mtx=1
For mean correction.
mtx=2
For trend correction.
Constraint: if ic=0, 0mtx2
If covariances are supplied (ic0), mtx is not used.
3:     px doubleInput
On entry: if covariances are to be calculated by the function (ic=0), px must specify the proportion of the data (totalled over both ends) to be initially tapered by the split cosine bell taper.
If covariances are supplied ic0, px must specify the proportion of data tapered before the supplied covariances were calculated and after any mean or trend correction. px is required for the calculation of output statistics. A value of 0.0 implies no tapering.
Constraint: 0.0px1.0.
4:     iw IntegerInput
On entry: the choice of lag window.
iw=1
Rectangular.
iw=2
Bartlett.
iw=3
Tukey.
iw=4
Parzen.
Constraint: 1iw4.
5:     mw IntegerInput
On entry: M, the ‘cut-off’ point of the lag window. Windowed covariances at lag M or greater are zero.
Constraint: 1mwnx.
6:     ic IntegerInput
On entry: indicates whether covariances are to be calculated in the function or supplied in the call to the function.
ic=0
Covariances are to be calculated.
ic0
Covariances are to be supplied.
7:     nc IntegerInput
On entry: the number of covariances to be calculated in the function or supplied in the call to the function.
Constraint: mwncnx.
8:     c[nc] doubleInput/Output
On entry: if ic0, c must contain the nc covariances for lags from 0 to nc-1, otherwise c need not be set.
On exit: if ic=0, c will contain the nc calculated covariances.
If ic0, the contents of c will be unchanged.
9:     kc IntegerInput
On entry: if ic=0, kc must specify the order of the fast Fourier transform (FFT) used to calculate the covariances.
If ic0, that is covariances are supplied, kc is not used.
Constraint: kcnx+nc.
10:   l IntegerInput
On entry: L, the frequency division of the spectral estimates as 2πL . Therefore it is also the order of the FFT used to construct the sample spectrum from the covariances.
Constraint: l2×mw-1.
11:   lg_spect Nag_LoggedSpectraInput
On entry: indicates whether unlogged or logged spectral estimates and confidence limits are required.
lg_spect=Nag_Unlogged
Unlogged.
lg_spect=Nag_Logged
Logged.
Constraint: lg_spect=Nag_Unlogged or Nag_Logged.
12:   nxg IntegerInput
On entry: the dimension of the array xg.
Constraints:
  • if ic=0, nxgmaxkc,l;
  • if ic0, nxgl.
13:   xg[nxg] doubleInput/Output
On entry: if the covariances are to be calculated, then xg must contain the nx data points. If covariances are supplied, xg may contain any values.
On exit: contains the ng spectral estimates, f^ωi, for i=0,1,,L/2 in xg[0] to xg[ng-1] respectively (logged if lg_spect=Nag_Logged). The elements xg[i-1], for i=ng+1,,nxg contain 0.0.
14:   ng Integer *Output
On exit: the number of spectral estimates, L/2+1, in xg.
15:   stats[4] doubleOutput
On exit: four associated statistics. These are the degrees of freedom in stats[0], the lower and upper 95% confidence limit factors in stats[1] and stats[2] respectively (logged if lg_spect=Nag_Logged), and the bandwidth in stats[3].
16:   fail NagError *Input/Output
The NAG error argument (see Section 3.7 in How to Use the NAG Library and its Documentation).

6
Error Indicators and Warnings

NE_ALLOC_FAIL
Dynamic memory allocation failed.
See Section 2.3.1.2 in How to Use the NAG Library and its Documentation for further information.
NE_BAD_PARAM
On entry, argument value had an illegal value.
NE_CONFID_LIMITS
The calculation of confidence limit factors has failed.
Spectral estimates (logged if requested) are returned in xg, and degrees of freedom and bandwidth in stats.
NE_INT
On entry, ic=0 and mtx<0: mtx=value.
On entry, ic=0 and mtx>2: mtx=value.
On entry, iw=value.
Constraint: iw=1, 2, 3 or 4.
On entry, mw=value.
Constraint: mw1.
On entry, nx=value.
Constraint: nx1.
NE_INT_2
On entry, l=value and mw=value.
Constraint: l2×mw-1.
On entry, mw=value and nx=value.
Constraint: mwnx.
On entry, nc=value and mw=value.
Constraint: ncmw.
On entry, nc=value and nx=value.
Constraint: ncnx.
On entry, nxg=value and l=value.
Constraint: if ic0, nxgl.
NE_INT_3
On entry, kc=value, nx=value and nc=value.
Constraint: if ic=0, kcnx+nc.
On entry, nxg=value, kc=value and l=value.
Constraint: if ic=0, nxgmaxkc,l.
NE_INTERNAL_ERROR
An internal error has occurred in this function. Check the function call and any array sizes. If the call is correct then please contact NAG for assistance.
See Section 2.7.6 in How to Use the NAG Library and its Documentation for further information.
NE_NO_LICENCE
Your licence key may have expired or may not have been installed correctly.
See Section 2.7.5 in How to Use the NAG Library and its Documentation for further information.
NE_REAL
On entry, px=value.
Constraint: px1.0.
On entry, px=value.
Constraint: px0.0.
NE_SPECTRAL_ESTIMATES
One or more spectral estimates are negative.
Unlogged spectral estimates are returned in xg, and the degrees of freedom, unloged confidence limit factors and bandwidth in stats.

7
Accuracy

The FFT is a numerically stable process, and any errors introduced during the computation will normally be insignificant compared with uncertainty in the data.

8
Parallelism and Performance

nag_tsa_spectrum_univar_cov (g13cac) is threaded by NAG for parallel execution in multithreaded implementations of the NAG Library.
nag_tsa_spectrum_univar_cov (g13cac) makes calls to BLAS and/or LAPACK routines, which may be threaded within the vendor library used by this implementation. Consult the documentation for the vendor library for further information.
Please consult the x06 Chapter Introduction for information on how to control and interrogate the OpenMP environment used within this function. Please also consult the Users' Note for your implementation for any additional implementation-specific information.

9
Further Comments

nag_tsa_spectrum_univar_cov (g13cac) carries out two FFTs of length kc to calculate the covariances and one FFT of length l to calculate the sample spectrum. The time taken by the function for an FFT of length n is approximately proportional to nlogn (but see Section 9 in nag_sum_fft_realherm_1d (c06pac) for further details).

10
Example

This example reads a time series of length 256. It selects the mean correction option, a tapering proportion of 0.1, the Parzen smoothing window and a cut-off point for the window at lag 100. It chooses to have 100 auto-covariances calculated and unlogged spectral estimates at a frequency division of 2π/200. It then calls nag_tsa_spectrum_univar_cov (g13cac) to calculate the univariate spectrum and statistics and prints the autocovariances and the spectrum together with its 95% confidence multiplying limits.

10.1
Program Text

Program Text (g13cace.c)

10.2
Program Data

Program Data (g13cace.d)

10.3
Program Results

Program Results (g13cace.r)